  1. J

    240v electrical line question

    If the electrical panel is within site of the water heater then no shut off needed. Just turn off the breaker.
  2. J

    40 amp sub panel

    You don't need a 40 amp breaker in the sub panel. You need a 40 amp breaker in the panel feeding the sub panel. Where are getting the info that you need a main in the sub panel? I am not aware of that rule.
  3. J

    How to disconnect this silver connector to my plumbing?

    It is a crimp connection. You can't disconnect it unless you saw it off.
  4. J

    Air compressor with mag starter

    In my opinion a mag starter is the wrong device for the compressor. All you need is a disconnect on the wall and the pressure switch turns the motor on and off.
  5. J

    Purpose of Large gap in brick

    most like they are for drainage to allow any water build up to drain from behind the wall.
  6. J

    Service drop amps

    Your sevice can supply up the value of your main breaker.
  7. J

    1 source, 3 switches [in one gang box] to 3 lights, but 1 light needs to power an outlet.

    If you use 14/2 then you must use a 15 amp breaker. If you want 20 amps then you must use #12 for all the cables.
  8. J

    Replacing fuses with breakers

    The first two option are not to code. I would not use anyone who suggested that option. When replacing the panel you have to meet the clearance requirements. Option 3 is the best. You can use GFCI breakers and replace the receptacle with three prong versions. they will not be grounded but will...
  9. J

    Underground PVC drain pipes pulled apart.

    Use a rubber coupling. You can slide it onto one pipe, align them and slide back onto the other pipe. They come in all sizes and brands.
  10. J

    Installing 4x8 wall panel directly to stud

    You can install panels direct to the stud.
  11. J

    White powder in wall

    The powder will brush off but then you need to address the moisture issue. Find where it is coming from and repair the issue. If this is a basement maybe all you need is a dehumidifier.
  12. J

    White powder in wall

    It is effervescence from moisture.
  13. J

    Combining 12 AWG and 10 AWG in one circuit

    It is not against code to use 10 on a 20 amp circuit but as you have discovered, working with #10 is a pain for lighting.
  14. J

    Electric Dryer-Drum Rotates but no heat

    It could be the power to the dryer. If one of the hot lines is out the motor will still run but no heat. I would try turning off the breaker and back on as a first step.
  15. J

    Search Engine Limitations

    You will get different results from different search engines. I normally use duckduckgo, but if I am not getting results I will try google.
  16. J

    Disassembling a Brick House from the Inside.

    There could be reasons the brick was needed such as fire stopping or support column.
  17. J

    Unoccupied House Maintenance

    With no heat you need to get the water out of traps or they will freeze and crack.
  18. J

    Unoccupied House Maintenance

    The traps under the sinks and tubs and the toilet should be drained and filled with rv antifreeze. Only the toilet bowl needs antifreeze. The tank can be left empty.
  19. J

    Cleaning a chainsaw

    pressure washer??
  20. J

    Cleaning a chainsaw

    I would take the chain and bar off and brush and scrape. Then reassemble.