I have searched the internet but not entirely comfortable on the results to order a replacement. The parts sheet for the Heat Pump on the contactor shows: CSG part# CTR-0639 with the following description: Single Pole normally open with thru bar. Contacts 240V, FLA 25.0, LRA 150.0; Coil 24V

On the old contactor itself that has a large sticker on it: reading left to right-
General Electric
Volts AC 277 480 600
Full Load Amperes 35
Locked Rotor Amperes:
>>1 PH (Blank)
>> Per? ( rubbed thru)150 125 100
Resistive Amperes Per Pole 35

At the very bottom on the same tag: CR353CB3AH1AG

Very small white tag near the contactor's mounting base: ;
24v 60hz
24v 50hz
55-827h
 
Power contactors / definate purpose contactors for condenser units are pretty generic .

As long as the replacement contactor will phisically fit , brand is not critical .

If the coil voltage , line voltage , amperage , is the same . If there is room to fit , I like to go up at least 1 size in amperage .

( Note , for HVAC , coil voltage is usually 24 VAC . )

Wyr
God bless
 
Are you sure your existing contractor lists the FLA at 35? That doesn’t seem right when looking at the rest of the specs you listed for that contractor.
 